Sign In | Join Free | My himfr.com
Home > Modbus RTU IO Module >

GCOS PT100 Modbus RTU IO Module For Remote Data Acquisition Relay Isolation

CWT(HK) Co., Limited
Contact Now
    Buy cheap GCOS PT100 Modbus RTU IO Module For Remote Data Acquisition Relay Isolation from wholesalers
     
    Buy cheap GCOS PT100 Modbus RTU IO Module For Remote Data Acquisition Relay Isolation from wholesalers
    • Buy cheap GCOS PT100 Modbus RTU IO Module For Remote Data Acquisition Relay Isolation from wholesalers

    GCOS PT100 Modbus RTU IO Module For Remote Data Acquisition Relay Isolation

    Ask Lasest Price
    Brand Name : CWT
    Model Number : CWT-MB
    Price : Western Union, L/C, T/T
    Supply Ability : Western Union, L/C, T/T
    • Product Details
    • Company Profile

    GCOS PT100 Modbus RTU IO Module For Remote Data Acquisition Relay Isolation

    SCADA RS485 Ethernet Modbus RTU IO Module For Remote Data Acquisition


    CWT-MB series Modbus IO module series with multi-channel DI/DO/AI/PT100 input. This module is designed for the whole industry, power supply, signal inputs and outputs, RS232 and RS485 interface(option Ethernet), interference protection designed to ensure data accuracy and reliability. RS485 communication interface performs MODBUS RTUprotocol, can be directly connected with the various types of PLC, DCS system, operator panel and a variety of configuration software.


    System parameters

    CPU32-bit ATMEL ARM, 72MHZ
    OSGCOS,10ms scheduling mechanism
    Power7-35VDC @2W, power supply reverse protection, isolation design
    InstallationDIN rail mounting or screw fixing
    Working Environment-40℃~85℃,5%~95%RH(non-condensing)
    ProtectionIP20
    Watchdog1.5m guard

    Series port parameters

    Port type1RS485 & 1RS232
    ProtectionDCDC isolation design, 2500V lightning protection, ESD, overvoltage, overcurrent protection
    Baud rate1200~115200,default 9600
    ParityEven, Odd, None
    start bit1 bit
    data bits8 bit
    Stopbits1,2bits
    ProtocolMODBUS RTU
    default9600.N.8.1,slave id is 1

    Analog input

    Input type4~20mA<default>,option: 0~20mA/0~5/1~5/0~10V
    Precision0.1%,16 bit
    Refresh rate0.01m

    Digital input

    ON signal level5-30VDC,6mA@24VDC
    OFF signal level0-3VDC
    Protectionoptocoupler isolation, 2500V lightning protection, overvoltage, overcurrent protection
    sample rate0.01m

    Digital output

    Output typenormal open relay or Transistor output
    Isolationoptocoupler isolation& relay isolation
    Resistive load5A/250VAC, 5A/30VDC
    Response time≤0.01s

    PT100 Input

    Input typePT100
    Precision0.1℃
    Measure range-200℃ to 320℃